The water chiller is applicable to cooling the moulds use in the plastic molding processing machines, be capable of improve the products surface smoothness in large, to reduce the grain mark on the surface of the plastic products and internal stress, avoid to shrink and deform the products, easy to demoulding and quick to products forming, enlarge to improve the effeciency of plastic moulding machines accordingly. | ||||||||||||||||
1.Famous brand new compressors,high efficient shell condensers and evaporators -- excellent cooling,quiet with low electric consumption. | ||||||||||||||||
2.P.I.D. Microprocessor control--easy to operate,accurately maintains temperature range from 3℃ to 50℃ | ||||||||||||||||
3.Special open type reservoir tank with stainless steel -- easy to clean and maintain. | ||||||||||||||||
4.Well design and reasonable Pipelines--ensures power supply and saves energy. | ||||||||||||||||
5.Current-overload protector,high-and-low pressure switches,electronic time delayer,fault display system--Safe and durable. | ||||||||||||||||
6.Liquid crystal display showing temperatures of outlet and inlet chill water-provides visualized and direct setting. | ||||||||||||||||
7.Single,double or quadruple compressors combination available--economic and effcient. | ||||||||||||||||
8.Industrially designed--elegant and economic with friendly human-machine connections. | ||||||||||||||||
SPECIFICATIONS | ||||||||||||||||
Model | Unit | HVA-1 | HVA-2 | HVA-3 | HVA-4 | HVA-5 | HVA-8 | HVA-10 | ||||||||
Cooling Capacity | KW | 2.77 | 5.28 | 7.91 | 12.9 | 15.22 | 23.8 | 30.5 | ||||||||
Kcal/h | 2382 | 4541 | 6803 | 11094 | 13091 | 20468 | 26230 | |||||||||
Input Power | KW | 0.89 | 1.77 | 2.8 | 4.5 | 5.2 | 3x2 | 4.5x2 | ||||||||
Compressor | Rated Power | HP | 1 | 2 | 3 | 5 | 6 | 4x2 | 5x2 | |||||||
Power | 1PH-220V/50HZ | 3PH-380V/50HZ( 200V/220V/415V 50HZ/60HZ ) | ||||||||||||||
Type | Water Tank With Coil(Shell And Tube) | |||||||||||||||
Evaporator | Pipe Diameter | inch | 6' | 6' | 1'' | 1'' | 1'' | 2'' | 2'' | |||||||
Type | R22 | |||||||||||||||
Refrigerant | /Quantity | KG | 1.6 | 1.8 | 2 | 2 | 2.5 | 4 | 5 | |||||||
Type | ||||||||||||||||
Water Condenser | Pipe Diameter | inch | 1'' | 1'' | 1'' | 2'' | 2'' | |||||||||
Cooling Water Flow | m3/h | 0.476 | 0.908 | 1.36 | 2.22 | 2.6 | 3.95 | 4.42 | ||||||||
Type | Finned Copper Tybe + Low Noise Outer Rotor Fan | |||||||||||||||
Air Condenser | Fan Power | W | 85x1 | 85x1 | 135x1 | 135x2 | 135x2 | 420x2 | 420x2 | |||||||
/Water Tank Capacity | Liter | 20 | 20 | 50 | 60 | 60 | 110 | 110 | ||||||||
Pump | Power | KW | 0.37 | 0.37 | 0.37 | 0.37 | 0.75 | 0.75 | 0.75 | |||||||
HP | 0.5 | 0.5 | 0.5 | 0.5 | 1 | 1 | 1 | |||||||||
Distance | m | 23 | 23 | 23 | 23 | 35 | 13 | 13 | ||||||||
Flow Rate | L/min | 100 | 100 | 100 | 100 | 110 | 200 | 200 | ||||||||
/Safety Protection | ||||||||||||||||
High And Low Pressure Protection, Overload Protection,Over Temperature Protection,Phase Sequence Protection,etc. | ||||||||||||||||
Water Cooled | mm | 935* 500*883 | 935*500*883 | 935*500*883 | 1270*650*1413 | 1270*650*1413 | ||||||||||
Dimensions(L*W*H) | 风冷/Air Cooled | mm | 800*490*898 | 795*566*1058 | 960*630*1073 | 1280*630*1118 | 1280*630*1118 | 1550*830*1543 | 1550*830*1543 | |||||||
Model | Unit | HVA-12 | HVA-15 | HVA-20 | HVA-25 | HVA-30 | HVA-40 | HVA-50 | ||||||||
Cooling Capacity | KW | 34.3 | 45 | 61 | 69 | 92 | 122 | 136 | ||||||||
Kcal/h | 29498 | 38700 | 52460 | 59340 | 79120 | 104920 | 117476 | |||||||||
Input Power | KW | 10 | 4.5x3 | 9x2 | 10x2 | 9x3 | 9x4 | 9.4x4 | ||||||||
Compressor | Rated Power | HP | 6x2 | 5x3 | 10x2 | 12.5x2 | 10x3 | 10x4 | 12.5x4 | |||||||
Power | 3PH-380V/50HZ( 200V/220V/415V 50HZ/60HZ ) | |||||||||||||||
Type | Water Tank With Coil(Shell And Tube) | |||||||||||||||
Evaporator | Pipe Diameter | inch | 2'' | 2'' | 2.5'' | 2.5'' | 3'' | 3'' | 3'' | |||||||
Type | R22 | |||||||||||||||
Refrigerant | /Quantity | KG | 5 | 7.5 | 11 | 11 | 12 | 18 | 18 | |||||||
Type | ||||||||||||||||
Water Condenser | Pipe Diameter | inch | 2'' | 2'' | 2.5'' | 2.5'' | 3'' | 3'' | 3'' | |||||||
Cooling Water Flow | m3/h | 5.03 | 7.1 | 8.84 | 10.06 | 13.6 | 17.75 | 21.9 | ||||||||
Type | Finned Copper Tybe + Low Noise Outer Rotor Fan | |||||||||||||||
Air Condenser | Fan Power | W | 550x2 | 750x2 | 550x3 | 750x3 | 800x3 | 800x3 | 800x4 | |||||||
/Water Tank Capacity | Liter | 110 | 200 | 350 | 350 | 420 | 420 | 420 | ||||||||
Pump | Power | KW | 0.75 | 1.5 | 1.5 | 2.2 | 2.2 | 4 | 4 | |||||||
HP | 1 | 2 | 2 | 3 | 3 | 5 | 5 | |||||||||
Distance | m | 13 | 15 | 15 | 16 | 16 | 16 | 16 | ||||||||
Flow Rate | L/min | 200 | 360 | 360 | 650 | 650 | 700 | 700 | ||||||||
/Safety Protection | ||||||||||||||||
High And Low Pressure Protection, Overload Protection,Over Temperature Protection,Phase Sequence Protection,etc. | ||||||||||||||||
Water Cooled | mm | 1270*650*1413 | 1270*750*1413 | 1880*880*1650 | 1880*880*1650 | 1880*880*1650 | 2150*1080*1950 | 2150*1080*1950 | ||||||||
Dimensions(L*W*H) | 风冷/Air Cooled | mm | 1550*830*1543 | 1850*1000*1640 | 2150*1000*1820 | 2400*1150*1740 | 2600*1150*1940 | 2150*2000*1820 | 2400*2250*1840 | |||||||
Note:1.Cooling Capacity is calculated based on:inlet/outlet chilled fluid temperature:12℃/7℃,inlet/outlet cooling water temperature:30℃/35℃. | ||||||||||||||||
2.Working condition:Chilled fluid temperature:from 5℃ to35℃. Inlet/outlet chilled fluid Temperature difference:from 3℃ to 8℃. | ||||||||||||||||
Cooling water temperature:from 18℃ to 37℃,Inlet/outlet cooling water Temperature difference:from 3.5℃ to 10℃. | ||||||||||||||||
We reserve the right to modify above information without prior notice. | ||||||||||||||||
The water chiller is applicable to cooling the moulds use in the plastic molding processing machines, be capable of improve the products surface smoothness in large, to reduce the grain mark on the surface of the plastic products and internal stress, avoid to shrink and deform the products, easy to demoulding and quick to products forming, enlarge to improve the effeciency of plastic moulding machines accordingly. | ||||||||||||||||
1.Famous brand new compressors,high efficient shell condensers and evaporators -- excellent cooling,quiet with low electric consumption. | ||||||||||||||||
2.P.I.D. Microprocessor control--easy to operate,accurately maintains temperature range from 3℃ to 50℃ | ||||||||||||||||
3.Special open type reservoir tank with stainless steel -- easy to clean and maintain. | ||||||||||||||||
4.Well design and reasonable Pipelines--ensures power supply and saves energy. | ||||||||||||||||
5.Current-overload protector,high-and-low pressure switches,electronic time delayer,fault display system--Safe and durable. | ||||||||||||||||
6.Liquid crystal display showing temperatures of outlet and inlet chill water-provides visualized and direct setting. | ||||||||||||||||
7.Single,double or quadruple compressors combination available--economic and effcient. | ||||||||||||||||
8.Industrially designed--elegant and economic with friendly human-machine connections. | ||||||||||||||||
SPECIFICATIONS | ||||||||||||||||
Model | Unit | HJW-1 | HJW-2 | HJW-3 | HJW-4 | HJW-5 | HJW-8 | HJW-10 | ||||||||
Cooling Capacity | KW | 2.77 | 5.28 | 7.91 | 12.9 | 15.22 | 23.8 | 30.5 | ||||||||
Kcal/h | 2382 | 4541 | 6803 | 11094 | 13091 | 20468 | 26230 | |||||||||
Input Power | KW | 0.89 | 1.77 | 2.8 | 4.5 | 5.2 | 3x2 | 4.5x2 | ||||||||
Compressor | Rated Power | HP | 1 | 2 | 3 | 5 | 6 | 4x2 | 5x2 | |||||||
Power | 1PH-220V/50HZ | 3PH-380V/50HZ( 200V/220V/415V 50HZ/60HZ ) | ||||||||||||||
Type | Water Tank With Coil(Shell And Tube) | |||||||||||||||
Evaporator | Pipe Diameter | inch | 6' | 6' | 1'' | 1'' | 1'' | 2'' | 2'' | |||||||
Type | R22 | |||||||||||||||
Refrigerant | Quantity | KG | 1.6 | 1.8 | 2 | 2 | 2.5 | 4 | 5 | |||||||
Type | ||||||||||||||||
Water Condenser | Pipe Diameter | inch | 1'' | 1'' | 1'' | 2'' | 2'' | |||||||||
Cooling Water Flow | m3/h | 0.476 | 0.908 | 1.36 | 2.22 | 2.6 | 3.95 | 4.42 | ||||||||
Type | Finned Copper Tybe + Low Noise Outer Rotor Fan | |||||||||||||||
Air Condenser | an Power | W | 85x1 | 85x1 | 135x1 | 135x2 | 135x2 | 420x2 | 420x2 | |||||||
Water Tank Capacity | Liter | 20 | 20 | 50 | 60 | 60 | 110 | 110 | ||||||||
Pump | Power | KW | 0.37 | 0.37 | 0.37 | 0.37 | 0.75 | 0.75 | 0.75 | |||||||
HP | 0.5 | 0.5 | 0.5 | 0.5 | 1 | 1 | 1 | |||||||||
Distance | m | 23 | 23 | 23 | 23 | 35 | 13 | 13 | ||||||||
Flow Rate | L/min | 100 | 100 | 100 | 100 | 110 | 200 | 200 | ||||||||
Safety Protection | ||||||||||||||||
High And Low Pressure Protection, Overload Protection,Over Temperature Protection,Phase Sequence Protection,etc. | ||||||||||||||||
Water Cooled | mm | 935* 500*883 | 935*500*883 | 935*500*883 | 1270*650*1413 | 1270*650*1413 | ||||||||||
Dimensions(L*W*H) | Air Cooled | mm | 800*490*898 | 795*566*1058 | 960*630*1073 | 1280*630*1118 | 1280*630*1118 | 1550*830*1543 | 1550*830*1543 | |||||||
Model | Unit | HJW-12 | HJW-15 | HJW-20 | HJW-25 | HJW-30 | HJW-40 | HJW-50 | ||||||||
Cooling Capacity | KW | 34.3 | 45 | 61 | 69 | 92 | 122 | 136 | ||||||||
Kcal/h | 29498 | 38700 | 52460 | 59340 | 79120 | 104920 | 117476 | |||||||||
nput Power | KW | 10 | 4.5x3 | 9x2 | 10x2 | 9x3 | 9x4 | 9.4x4 | ||||||||
Compressor | Rated Power | HP | 6x2 | 5x3 | 10x2 | 12.5x2 | 10x3 | 10x4 | 12.5x4 | |||||||
Power | 3PH-380V/50HZ( 200V/220V/415V 50HZ/60HZ ) | |||||||||||||||
Type | Water Tank With Coil(Shell And Tube) | |||||||||||||||
Evaporator | Pipe Diameter | inch | 2'' | 2'' | 2.5'' | 2.5'' | 3'' | 3'' | 3'' | |||||||
Type | R22 | |||||||||||||||
Refrigerant | Quantity | KG | 5 | 7.5 | 11 | 11 | 12 | 18 | 18 | |||||||
Type | ||||||||||||||||
Water Condenser | Pipe Diameter | inch | 2'' | 2'' | 2.5'' | 2.5'' | 3'' | 3'' | 3'' | |||||||
Cooling Water Flow | m3/h | 5.03 | 7.1 | 8.84 | 10.06 | 13.6 | 17.75 | 21.9 | ||||||||
Type | Finned Copper Tybe + Low Noise Outer Rotor Fan | |||||||||||||||
Air Condenser | Fan Power | W | 550x2 | 750x2 | 550x3 | 750x3 | 800x3 | 800x3 | 800x4 | |||||||
Water Tank Capacity | Liter | 110 | 200 | 350 | 350 | 420 | 420 | 420 | ||||||||
Pump | Power | KW | 0.75 | 1.5 | 1.5 | 2.2 | 2.2 | 4 | 4 | |||||||
HP | 1 | 2 | 2 | 3 | 3 | 5 | 5 | |||||||||
Distance | m | 13 | 15 | 15 | 16 | 16 | 16 | 16 | ||||||||
Flow Rate | L/min | 200 | 360 | 360 | 650 | 650 | 700 | 700 | ||||||||
Safety Protection | ||||||||||||||||
High And Low Pressure Protection, Overload Protection,Over Temperature Protection,Phase Sequence Protection,etc. | ||||||||||||||||
Water Cooled | mm | 1270*650*1413 | 1270*750*1413 | 1880*880*1650 | 1880*880*1650 | 1880*880*1650 | 2150*1080*1950 | 2150*1080*1950 | ||||||||
Dimensions(L*W*H) | Air Cooled | mm | 1550*830*1543 | 1850*1000*1640 | 2150*1000*1820 | 2400*1150*1740 | 2600*1150*1940 | 2150*2000*1820 | 2400*2250*1840 | |||||||
Note:1.Cooling Capacity is calculated based on:inlet/outlet chilled fluid temperature:12℃/7℃,inlet/outlet cooling water temperature:30℃/35℃. | ||||||||||||||||
2.Working condition:Chilled fluid temperature:from 5℃ to35℃. Inlet/outlet chilled fluid Temperature difference:from 3℃ to 8℃. | ||||||||||||||||
Cooling water temperature:from 18℃ to 37℃,Inlet/outlet cooling water Temperature difference:from 3.5℃ to 10℃. | ||||||||||||||||
We reserve the right to modify above information without prior notice. | ||||||||||||||||